• 文献标题:   Electrochemical Determination of the KRAS Genetic Marker for Colon Cancer with Modified Graphete and Graphene Paste Electrodes
  • 文献类型:   Article
  • 作  者:   ALOGAIDI AJM, STEFANVAN STADEN RI, GUGOASA LA, ROSU MC, SOCACI C
  • 作者关键词:   colon cancer, differential pulse voltammetry, electrochemical sensor, kras, scanning electron microscopy, transmission electron microscopy, whole blood
  • 出版物名称:   ANALYTICAL LETTERS
  • ISSN:   0003-2719 EI 1532-236X
  • 通讯作者地址:   Natl Inst Res Electrochem Condensed Matter
  • 被引频次:   2
  • DOI:   10.1080/00032719.2018.1453516
  • 出版年:   2018

▎ 摘  要

The determination of KRAS was performed using electrochemical sensing devices based on graphite and graphene pastes, modified with a phthalocyanine-boron dipyrromethene (BODIPY) and azulenes dyes. The limits of quantification for KRAS were 1.54x10(-4)mu g/mL using the sensor based on the phthalocyanine-BODIPY dye and graphite, 2.64x10(-7)mu g/mL using the sensor based on 2,6-bis((E)-2-(furan-2-yl)vinyl)-4-(4,6,8-trimethylazulen-1-yl)pyridine/TiO2Pt/reduced graphene oxide, and 3.84x10(-3)mu g/mL using the sensor based on 2,6-bis((E)-2-(thiophen-3-yl)vinyl)-4-(4,6,8-trimethylazulen-1-yl)pyridine/TiO2Pt/reduced graphene oxide. Recovery measurements demonstrated the suitable analytical performance of these sensors for the early detection of colon cancer by the analysis of whole blood samples.