• 文献标题:   Preparation, Mechanical Properties, and Biocompatibility of Graphene Oxide-Reinforced Chitin Monofilament Absorbable Surgical Sutures
  • 文献类型:   Article
  • 作  者:   ZHANG W, YIN B, XIN Y, LI L, YE GL, WANG JX, SHEN JF, CUI X, YANG QH
  • 作者关键词:   graphene oxide, chitin, suture, biocompatibility, mechanical strength
  • 出版物名称:   MARINE DRUGS
  • ISSN:   1660-3397
  • 通讯作者地址:   Guangdong Ocean Univ
  • 被引频次:   1
  • DOI:   10.3390/md17040210
  • 出版年:   2019

▎ 摘  要

Chitin (CT) is a good material to prepare surgical sutures due to its conspicuous biological characteristics. However, the poor mechanical strength of pure CT sutures limits its application. In order to improve its strength, a composite monofilament absorbable suture was prepared in this study using graphene oxide and chitin (GO-CT) using a green method. FT-IR spectra showed that GO-CT contained the characteristic functional groups of GO and CT, indicating that a GO-CT suture was successfully obtained. With the addition of a small amount of GO (1.6wt% solution) in chitin, the breaking tensile strength, knot strength, and knot-pull strength of the GO-CT suture were significantly improved compared to the CT suture. The biocompatibility of the GO-CT suture in vitro was checked by tetrazolium-based colorimetric assays and no cytotoxicity to L929 cells was found. In vivo, the subcutaneous implantation of GO-CT sutures in the dorsal skin of rats found no abnormalities by hematoxylin-eosin staining. Furthermore, there were no significant changes in the gene expression of the inflammatory mediators, interleukin 1 (IL-1), tumor necrosis factor-, IL-6, IL-17A, interferon-, or IL-10; however, the expression of transforming growth factor was significantly increased in the first week. In summary, GO-CT sutures may have potential as a suture material in the clinic.