▎ 摘 要
The paper is the study of electric resistance of a graphene layer washed by a liquid with different flow rate parameters. Experiments demonstrate that if the fabricated composite (graphene upon a PET/EVA polymeric substrate) is submerged into distilled water, the sample resistance increases by 120 %. Meanwhile, the flow of liquid near the graphene layer decreases this gain in the electric conductivity. The effect offers a general design of a flow rate sensor based on the graphene layer taken as a flow-sensitive matrix. The study demonstrates that this design of graphene flow sensor (tested for distilled water) exhibits a linear dependency of the sensor resistance on the flow rate.