• 文献标题:   PEDOT-reduced graphene oxide-silver hybrid nanocomposite modified transducer for the detection of serotonin
  • 文献类型:   Article
  • 作  者:   SADANANDHAN NK, CHERIYATHUCHENAARAMVALLI M, DEVAKI SJ, MENON ARR
  • 作者关键词:   reduced graphene oxide, liquid crystal, poly 3 4ethylene dioxythiophene, silver nanoparticle, voltammetry, serotonin
  • 出版物名称:   JOURNAL OF ELECTROANALYTICAL CHEMISTRY
  • ISSN:   1572-6657 EI 1873-2569
  • 通讯作者地址:   CSIR Natl Inst Interdisciplinary Sci Technol
  • 被引频次:   17
  • DOI:   10.1016/j.jelechem.2017.04.027
  • 出版年:   2017

▎ 摘  要

We have developed PEDOT - reduced graphene oxide - silver hybrid nanocomposite (PEDOTNTs/rGO/Ag NPs) modified electrode as a transducer for the detection of serotonin. Structure and properties of the nanocomposites were characterized by XPS, XRD, SEM, TEM, FT-IR, UV-Visible, and Raman spectroscopy. The electrochemical impedance spectroscopic (EIS) results showed a very low charge transfer resistance (198 Omega) for the modified electrode and its sensing performance towards serotonin studied by various electrochemical techniques such as cyclic voltammetry (CV), differential pulse voltammetry (DPV) and chronoamperometry (CA). PEDOTNTs/rGO/ AgNPs/GCE showed better performance by DPV with a lower detection limit of 0.1 nM with high operational stability, reproducibility (inter- and intra-electrode - 2.3%) response time (8 s) and sensitivity (14.304 mu A mM(-1)/cm(2)). It also showed a liner range from 1 nM to 0.5 mM (linear regression equation y = 6.33 e(-6) x + 0.153 e(-6)). The kinetics of serotonin oxidation was studied by chronoamperometry and the catalytic rate constant calculated as 1.647 x 10(3) mol(-1)Ls(-1). Later, the modified electrode demonstrated as a transducer for the selective detection of serotonin in the presence of ascorbic acid, uric add and tyrosine. Real sample analysis and interference studies suggested the modified electrode can be exploited in pharmaceutical and medical fields.