• 文献标题:   Electrodeposited Graphene and Gold Nanoparticle Modified Carbon Ionic Liquid Electrode for Sensitive Detection of Rutin
  • 文献类型:   Article
  • 作  者:   SUN W, WANG D, ZHANG YY, JU XM, YANG HX, CHEN YX, SUN ZF
  • 作者关键词:   carbon ionic liquid electrode, graphene, gold nanoparticle, rutin, electrochemistry
  • 出版物名称:   CHINESE JOURNAL OF ANALYTICAL CHEMISTRY
  • ISSN:   0253-3820
  • 通讯作者地址:   Hainan Normal Univ
  • 被引频次:   18
  • DOI:   10.3724/SP.J.1096.2013.20754
  • 出版年:   2013

▎ 摘  要

A carbon ionic liquid electrode (CILE) was prepared by using ionic liquid 1-hexylpyridinium hexafluorophosphate (HPPF6) as the binder and the modifier, and then it was further decorated with gold nanoparticles and graphene (GR) using step by step electrochemical method to get a modified electrode denoted as GR/Au/CILE. Electrochemical performance of GR/Au/CILE was greatly enhanced due to the presence of nano. gold and GR. Different electrochemical methods such as cyclic voltammetry, differential pulse voltammetry and chronocoulometry were used to investigate the electrochemical behaviors of rutin on GR/Au/CILE with the electrochemical parameters calculated. Under the optimal conditions the oxidation peak current of rutin was proportional to its concentration in the range of 8.0x10(-8)-8.0x10(-5) mol/L with the detection limit of 2.55 x 10(-8) mol/L (3 sigma). The proposed method was applied to the analysis of rutin tablet with satisfactory results.