• 文献标题:   Simultaneous Determination of Acetaminophen and Caffeine Based on Graphene Oxide/Cerium Hexacyanoferrate Modified Glassy Carbon Electrode
  • 文献类型:   Article
  • 作  者:   LU XC, HUANG KJ, WU ZW, HUANG SF, XU CX
  • 作者关键词:   differential pulse voltammetry, graphene oxide, cerium hexacyanoferrate, acetaminophen, caffeine
  • 出版物名称:   CHINESE JOURNAL OF ANALYTICAL CHEMISTRY
  • ISSN:   0253-3820
  • 通讯作者地址:   Xinyang Normal Univ
  • 被引频次:   8
  • DOI:   10.3724/SP.J.1096.2012.10531
  • 出版年:   2012

▎ 摘  要

Graphene oxide was coated on glassy carbon electrode and cerium hexacyanoferrate was then electrodeposited on the modified electrode. Scanning electron microscope was used to characterize the modified electrode. The electrochemical behaviors of acetaminophen and caffeine on the modified electrode were investigated by cyclic voltammetry and differential pulse voltammetry. The experimental results showed that the electrochemical respond of acetaminophen and caffeine at the modified electrode was significantly improved in acetate buffer solutions (pH 5.0). The concentration of acetaminophen and caffeine showed good linear relationships with the oxidation peak current in the range of 1.0 x 10(-7) - 6.0 x 10(-5) mol/L and 1.0 x 10(-6) - 1.3 x 10(-4) mol/L, with correlation coefficients of R = 0.990 and 0.992, respectively. The limits of detection for acetaminophen and caffeine were 5.0 x 10(-8) mol/L and 5.2 x 10(-7) mol/L (S/N = 3), respectively. The developed method was used to the determination of spiked urine samples with recoveries of 96.1% - 105.4%.