• 文献标题:   MODIFIED GRAPHITE/GRAPHENE DOT MICROSENSORS FOR THE ASSAY OF TRACE AMOUNTS OF LEAD AND CADMIUM IN WATER CATCHMENTS AREAS USING DIFFERENTIAL PULSE ANODIC STRIPPING VOLTAMMETRY
  • 文献类型:   Article
  • 作  者:   VAN STADEN JF, ARNOLD TATU GL
  • 作者关键词:   graphite/graphene dot microsensor, lead, cadmium, water catchments area
  • 出版物名称:   REVUE ROUMAINE DE CHIMIE
  • ISSN:   0035-3930
  • 通讯作者地址:   Natl Inst Res Dev Electrochem Condensed Matte
  • 被引频次:   0
  • DOI:   10.33224/rrch.2019.64.10.05
  • 出版年:   2019

▎ 摘  要

In this study, dot microsensors based on graphite/graphene paste modified with iron (II) phthalocyanine, nickel (II) phthalocyanine and 5,10,15,20-tetra(4pyridyl)21H, 23H porphine chloride tetrakis(methochloride) manganese(III) were used for the determination of trace amounts of lead and cadmium from various water catchments areas using differential pulse anodic stripping voltammetry. The response of the proposed dot microsensors were sensitive enough to detect very low levels of both metals ions in drinking water resources to take corrective action for the supply of safe and suitable drinking water. The lowest limits of quantification for lead is 0.00207 mu g L-1 and for cadmium 5.6 mu g L-1, with a correlation coefficient (R-2) between 0.9951 and 0.9981 for lead, and between 0.9951 and 0.9984 for cadmium. The recovery of Pb(II) and Cd(II) in water samples were higher than 93.06 % with RSD(%) values lower than 0.29%. These results of the proposed dot microsensors compared favorably with the results from a standard ISO certified method.