• 文献标题:   A nanocomposite prepared from reduced graphene oxide, gold nanoparticles and poly(2-amino-5-mercapto-1,3,4-thiadiazole) for use in an electrochemical sensor for doxorubicin
  • 文献类型:   Article
  • 作  者:   GHANBARI MH, SHANDOSTFARD F, SALEHZADEH H, GANJALI MR, IMAN M, RAHIMINASRABADI M, AHMADI F
  • 作者关键词:   reduced graphene oxide, gold nanoparticle, poly 2amino5mercapto1 3 4thiadiazole, doxorubicin, electrochemical sensor
  • 出版物名称:   MICROCHIMICA ACTA
  • ISSN:   0026-3672 EI 1436-5073
  • 通讯作者地址:   Baqiyatallah Univ Med Sci
  • 被引频次:   13
  • DOI:   10.1007/s00604-019-3761-6
  • 出版年:   2019

▎ 摘  要

A nanocomposite was prepared with reduced graphene oxide, gold nanoparticles and an electropolymerized film made from 2-amino-5-mercapto-1,3,4-thiadiazole. An electrochemical sensor for doxorubicin (DOX) was constructed by modifying a glassy carbon electrode (GCE) with the nanocomposite. The modified GCE was studied by electrochemical techniques which showed it to enable highly sensitive sensing of DOX. Response (typically measured at a typical working potential of -0.56 V vs. Ag/AgCl) is linear in the 30 pM to 30 nM and 30 nM to 30 mu M DOX concentration ranges, with a limit of detection (LOD) of 9 pM (at an S/N ratio of 3). The method was applied to the determination of DOX in serum and gave recoveries that ranged between 92 and 108%.