• 文献标题:   Electrochemical detection of dopamine in the presence of ascorbic acid using graphene modified electrodes
  • 文献类型:   Article
  • 作  者:   KIM YR, BONG S, KANG YJ, YANG Y, MAHAJAN RK, KIM JS, KIM H
  • 作者关键词:   dopamine, ascorbic acid, graphene, cyclic voltammetry, electrochemical impedance spectroscopy
  • 出版物名称:   BIOSENSORS BIOELECTRONICS
  • ISSN:   0956-5663
  • 通讯作者地址:   Seoul Natl Univ
  • 被引频次:   430
  • DOI:   10.1016/j.bios.2010.02.031
  • 出版年:   2010

▎ 摘  要

Dopamine plays a significant role in the function of human metabolism. It is important to develop sensitive sensor for the determination of dopamine without the interference by ascorbic acid. This paper reports the synthesis of graphene using a modified Hummer's method and its application for the electrochemical detection of dopamine. Electrochemical measurements were performed at glassy carbon electrode modified with graphene via drop-casting method. Cyclic voltammogram of ferri/ferrocyanide redox couple at graphene modified electrode showed an increased current intensity compared with glassy carbon electrode and graphite modified electrode. The decrease of charge transfer resistance was also analyzed by electrochemical impedance spectroscopy. The capacity of graphene modified electrode for selective detection of dopamine was confirmed in a sufficient amount of ascorbic acid (1 mM). The observed linear range for the determination of dopamine concentration was from 4 mu M to 100 mu M. The detection limit was estimated to be 2.64 mu M. (C) 2010 Elsevier BM. All rights reserved.