• 文献标题:   Electropolymerized Molecular Imprinting & Graphene Modified Electrode for Detection of Melamine
  • 文献类型:   Article
  • 作  者:   JI Z, CHEN W, WANG E, DENG RR
  • 作者关键词:   molecularly imprinted polymer, graphene, melamine, sensor
  • 出版物名称:   INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE
  • ISSN:   1452-3981
  • 通讯作者地址:   Chengdu Univ Technol
  • 被引频次:   1
  • DOI:   10.20964/2017.12.34
  • 出版年:   2017

▎ 摘  要

A new method for the determination of melamine (MEL) indirectly by the changes of differential pulse voltammetry (DPV) current of K-3[Fe(CN)(6)] probes after 10 min incubation (Delta I) has been established. It's based on the inhibitory effect of MEL on occupying the molecular recognition sites of surface of the electropolymerized molecular imprinting & graphene modified glassy carbon electrode (MIPPy/GR/GCE). The MIPPy/GR/GCE was characterized by cyclic voltammetry (CV), electrochemical impedance spectrometry (EIS) and scanning electron microscopy (SEM). The Delta I is linearly proportional to the negative logarithmic concentration of MEL over the range of 3.0x10(-8) similar to 1.0x10(-4) mol center dot L-1 (R = 0.9948), the detection limit is 1.02x10(-8) mol center dot L-1 (S/N = 3). The recoveries of samples are from102.65% to 108.02%, the result is satisfactory when it is used to analyze the real samples.