• 文献标题:   Reduced graphene oxide-supported gold dendrite for electrochemical sensing of acetaminophen
  • 文献类型:   Article
  • 作  者:   YU SM, LI HF, LI GE, NIU LT, LIU WL, DI X
  • 作者关键词:   gold dendrite, reduced graphene oxide, acetaminophen, electrochemical sensor
  • 出版物名称:   TALANTA
  • ISSN:   0039-9140 EI 1873-3573
  • 通讯作者地址:   Shenyang Pharmaceut Univ
  • 被引频次:   10
  • DOI:   10.1016/j.talanta.2018.03.011
  • 出版年:   2018

▎ 摘  要

A new nanocomposite was developed based on reduced graphene oxide (RGO) supported gold dendrite and applied for amperometric detection of acetaminophen. The RGO-gold dendrite composite was prepared by self assembly of poly (diallyldimethylammonium chloride) (PDDA) functionalized gold dendrite and poly (sodium 4-styrenesulfonate) (PSS) functionalized RGO. The composite electrode material was characterized by Scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDS), Ultraviolet-vis spectroscopy (UV), X-ray diffraction (XRD), Raman spectroscopy and X-ray photoelectron spectroscopy (XPS). The RGO-gold dendrite composite exhibited enhanced conductivity, catalytic activity and stability for acetaminophen oxidation and determination. The RGO-gold dendrite based electrochemical sensor is competent for detecting acetaminophen with a linear range from 0.07 mu M to 3000 mu M with a detection limit of 0.005 mu M (S/N = 3). Moreover, the sensor was applied for the detection of acetaminophen in tablets and urine samples, which holds great promise in pharmaceutical analysis.