▎ 摘 要
Yellow catfish (Pelteobagrus fulvidraco) is commonly contaminated by protease inhibitors because of the illegal use of antiviral drugs in aquaculture, so the determination of antiviral drugs is essential in food safety supervision. In this study, a novel sorbent, graphene and silica nanospheres composite (G/KCC-1), was synthesized for pipette-tip-based solid-phase extraction (PT-SPE) and purification of ritonavir, saquinavir, and indinavir in yellow catfish, followed by ultra-performance liquid chromatography and tandem mass spectrometry (UPLC-MS/MS) analysis. The wrinkly structure of G/KCC-1 with center-radial nanowrinkles enlarged the surface area and increased the capacity of absorbing the target analyte. With the proposed G/KCC-1 based PT-SPE UPLC-MS/MS method, the pH of sample solution, aspirating/dispensing cycles for extraction and elution were optimized to be 4.0, 25, and 10 respectively, and the eluting solvent was methanol/ammonia (95:5, v/v) with 0.02 M sodium chloride. This new method was further validated to be linear (correlation coefficient R-2, 0.9993-0.9996), sensitive (limit of detection, LOD