• 文献标题:   Determination of Oxytetracycline by a Graphene-Gold Nanoparticle-Based Colorimetric Aptamer Sensor
  • 文献类型:   Article
  • 作  者:   YUAN F, ZHAO HM, WANG XD, QUAN X
  • 作者关键词:   aptamer, colorimetry, enzyme mimetic, graphene/gold nanoparticle hybrid, oxytetracycline
  • 出版物名称:   ANALYTICAL LETTERS
  • ISSN:   0003-2719 EI 1532-236X
  • 通讯作者地址:   Dalian Univ Technol
  • 被引频次:   6
  • DOI:   10.1080/00032719.2016.1187160
  • 出版年:   2017

▎ 摘  要

A colorimetric aptamer sensor for the determination of oxytetracycline was developed based on the controllable peroxidase-like catalysis of a graphene/gold nanoparticle hybrid and the high affinity between oxytetracycline aptamers and oxytetracycline. The oxytetracycline aptamer was a single-stranded DNA sequence that was adsorbed on the interface of the hybrid, resulting in inhibition of the catalysis. The aptamer-oxytetracycline complex formed spontaneously following the addition of oxytetracycline, escaped from the hybrid, and recovered the catalytic ability that was inhibited by the aptamer. In the presence of hydrogen peroxide, the recovered hybrid oxidized a colorimetric reagent, causing a concomitant change in color. The whole process did not involve labeling and the color change was readily observed. This method provided a linear dynamic range for oxytetracycline from 0.17 to 0.50 mu M with a detection limit of 91 nM and a quantification limit of 0.17 mu M. In addition, the selectivity of the sensor was confirmed in the presence of high concentrations of potential interferents. This work is expected to encourage the development of additional simple and visible sensors for the determination of other pollutants.