• 文献标题:   Hierarchical nanocomposites of Co3O4/polyaniline nanowire arrays/reduced graphene oxide sheets for amino acid detection
  • 文献类型:   Article
  • 作  者:   WANG L, YE YJ, SHEN Y, WANG FP, LU XP, XIE YZ, CHEN SH, TAN HL, XU FG, SONG YH
  • 作者关键词:   biosensor, co3o4 nanoparticle, polyaniline, reduced graphene oxide, amino acida
  • 出版物名称:   SENSORS ACTUATORS BCHEMICAL
  • ISSN:   0925-4005
  • 通讯作者地址:   Jiangxi Normal Univ
  • 被引频次:   21
  • DOI:   10.1016/j.snb.2014.07.054
  • 出版年:   2014

▎ 摘  要

hierarchical nanocomposites of Co3O4/polyaniline (PANI) nanowire arrays/reduced graphene oxidesheets (rGO) was synthesized and characterized by scanning electron microscopy, X-ray diffraction, Fourier transform infrared spectroscopy and thermogravimetric analysis. The electrocatalytic oxidationand detection of cysteine or N-acetyl cysteine based on the nanocomposites modified glassy carbonelectrodes were investigated by cyclic voltammetry, double potential step chronoamperometry andamperometric responses. The results suggested that the modified electrode showed good electrocatalytic performance for cysteine and N-acetyl cysteine. Two linear calibration ranges of 12-1280 mu M and128020,800 mu M were obtained and the detection limit was estimated to be 4.0 mu M according to the firstlinear calibration range. For the N-acetyl cysteine, two linear ranges were from 12 to 2560 mu M and 2560to 24,800 mu M, respectively. The detection limit was estimated to be 5.2 mu M according to the first linearcalibration range. (C) 2014 Elsevier B. V. All rights reserved.