• 文献标题:   Electrochemical Sensing Fabricated with Ta2O5 Nanoparticle-Electrochemically Reduced Graphene Oxide Nanocomposite for the Detection of Oxytetracycline
  • 文献类型:   Article
  • 作  者:   MAGESA F, WU YY, DONG S, TIAN YL, LI GL, VIANNEY JM, BUZA J, LIU J, HE QG
  • 作者关键词:   ta2o5ergo composition, oxytetracycline, modified electrode, electrochemical reduced graphene oxide, voltammetric determination
  • 出版物名称:   BIOMOLECULES
  • ISSN:  
  • 通讯作者地址:   Hunan Univ Technol
  • 被引频次:   3
  • DOI:   10.3390/biom10010110
  • 出版年:   2020

▎ 摘  要

A novel tantalum pentoxide nanoparticle-electrochemically reduced graphene oxide nanocomposite-modified glassy carbon electrode (Ta2O5-ErGO/GCE) was developed for the detection of oxytetracycline in milk. The composition, structure and morphology of GO, Ta2O5, and Ta2O5-ErGO were characterized by X-ray diffraction (XRD) and scanning electron microscopy (SEM). Oxytetracycline electrochemical behavior on the bare GCE, GO/GCE, ErGO/GCE, and Ta2O5-ErGO/GCE was studied by cyclic voltammetry. The voltammetric conditions (including scan rate, pH, deposition potential, and deposition time) were systematically optimized. With the spacious electrochemical active area, the Ta2O5-ErGO/GCE showed a great magnification of the oxidation signal of oxytetracycline, while that of the other electrodes (GCE, GO/GCE, ErGO/GCE) could not reach the same level. Under the optimum conditions, the currents were proportional to the oxytetracycline concentration in the range from 0.2 to 10 mu M, and a low detection limit of 0.095 mu M (S/N = 3) was detectable. Moreover, the proposed Ta2O5-ErGO/GCE performed practically with satisfactory results. The preparation of Ta2O5-ErGO/GCE in the current work provides a minor outlook of detecting trace oxytetracycline in milk.