▎ 摘 要
Octadecyl-modified graphene (graphene-C18) was fabricated and used as adsorbent in hollow fiber liquid phase microextraction (HF-LPME) for the first time. The extraction performance of graphene-C18 reinforced BF-LPM:E was evaluated using chlorophenols as model analytes. The factors affecting the extraction efficiency, such as extraction time, pH of the sample solution, agitation rate, the concentration of graphene-C18 and salt addition were optimized. After the graphene-C18 reinforced BF-LPME of the chlorophenols from honey sample, the analytes were separated and determined by high-performance liquid chromatography. The linearity was observed in the range of 5.0-200.0 ng g(-1) for 2-chlorophenol and 3-chlorophenol, and 2.0-200.0 ng g(-1) for 2,3-dichlorophenol and 3,4-dichlorophenol, respectively. The limits of detection (S/N = 3) of the method were lower than 1.5 ng g(-1). The recoveries of the method were between 88% and 108%. The method is simple, sensitive and has been resoundingly applied to analysis of chlorophenols in honey samples.