▎ 摘 要
In this study, the flow boiling critical heat flux (CHF) using graphene oxide (GO)/water nanofluid was investigated under low pressure and low flow conditions. The 0.01 vol.% GO/water nanofluid is prepared for CHF enhancement test because recently, there are a lot of interests about graphene as an exceptional heat conduction material for thermal management and GO nanoparticles are more dispersed in water than graphene nanoparticles in terms of hydrophilicity. All experiments were carried out for round tubes with 1/2 in. diameter and 0.5 m heating length under low pressure and low flow (LPLF) at two fixed inlet temperatures (25 and 50 degrees C) and at four different mass fluxes (100, 150, 200 and 250 kg/m(2) s). It was found that the CHF of the GO/water nanofluid was more enhanced up to similar to 100% than the CHF of water as a base fluid. The causes of CHF enhancement were investigated through macroscopic observations, SEM observations and measurement of contact angles of the heated surfaces with depositions. Liquid film thickness affected by evaporation, entrainment and deposition mass transfer can be closely linked with wettability and GO properties. (C) 2013 Elsevier Ltd. All rights reserved.