• 文献标题:   Highly sensitive and selective detection of biothiols using graphene oxide-based "molecular beacon"-like fluorescent probe
  • 文献类型:   Article
  • 作  者:   GAO Y, LI Y, ZOU X, HUANG H, SU XG
  • 作者关键词:   biothiol, glutathione, cysteine, graphene oxide, thyminethymine mismatch
  • 出版物名称:   ANALYTICA CHIMICA ACTA
  • ISSN:   0003-2670 EI 1873-4324
  • 通讯作者地址:   Jilin Univ
  • 被引频次:   37
  • DOI:   10.1016/j.aca.2012.04.020
  • 出版年:   2012

▎ 摘  要

A fluorometric method for quantity analysis of biothiols was developed using a graphene oxide (GO)-based "molecular beacon"-like probe, which consisted of FITC labeled thymine (T)-rich single-stranded DNA (ssDNA), GO and Hg2+ ions. The labeled ssDNA containing T-T mismatches would self-hybridize to duplex in the presence of Hg2+, which can avoid its adsorption on GO and the fluorescence of this GO-based probe was recovered. The fluorescence of the probe quenched after the addition of biothiols such as glutathione (GSH) and cysteine (Cys) owing to thiol groups can selectively competitive ligation of Hg2+ ions with T-T mismatches. In the present work, the GO-based probe was used for the determination of GSH and Cys. Under the optimal conditions, a linear correlation was established between fluorescence intensity ratio I-0/I and the concentration of GSH in the range of 2.0 x 10(-9)-5.0 x 10(-7) mol L-1 with a detection limit of 1.0 x 10(-9) mol L-1. The linear range for Cys is from 5.0 x 10(-9) to 4.5 x 10(-7) mol L-1 with a detection limit of 2.0 x 10(-9) mol L-1. The proposed method was applied to the determination of GSH in human serum and cell extract samples with satisfactory results. (C) 2012 Elsevier B.V. All rights reserved.