▎ 摘 要
A novel and selective electrochemical sensing of nicotine is studied using copper tungstate decorated reduced graphene oxide nanocomposite (CuWO4/rGO) nafion (NO immobilized GC electrode (GCE). The CuWO4/rGO nanocomposite is synthesized using sonication method and characterized by HR-TEM (High resolution transmission electron microscopy), SEM (Scanning electron microscopy), FT-IR (Fourier transform infrared spectroscopy), SAED (Selected area of electron diffraction pattern), XRD (X-ray diffraction), Raman spectroscopy, Thermo gravimetric analysis (TGA) and EDX (Energy dispersive X-ray diffraction) techniques. The CuWO4/rGO/Nf immobilized GCE shows better electrocatalytic response for the detection of nicotine as compared to bare GCE. A better selectivity and sensitivity is achieved using CuWO4/rGO/Nf immobilized GCE to detect 0.1 mu M nicotine in the presence of 100-fold excess concentrations of different interferents. The present CuWO4/rGO/Nf immobilized GCE electrochemical sensor exhibits an ample range of sensing from 0.1 mu M to 0.9 mu M and the low detection limit is found to be 0.035 mu M (S/N = 3). Comparable results are achieved for the determination of nicotine in various real samples such as cigarettes (Gold flake and Wills) and urine samples with improved recoveries.