• 文献标题:   Biocompatibility and hemocompatibility of hydrothermally derived reduced it graphene oxide using soluble starch as a reducing agent
  • 文献类型:   Article
  • 作  者:   NARAYANAN KB, KIM HD, HAN SS
  • 作者关键词:   graphene, hydrothermal, soluble starch, cell viability, biocompatible, hemocompatible
  • 出版物名称:   COLLOIDS SURFACES BBIOINTERFACES
  • ISSN:   0927-7765 EI 1873-4367
  • 通讯作者地址:   Yeungnam Univ
  • 被引频次:   4
  • DOI:   10.1016/j.colsurfb.2019.110579
  • 出版年:   2020

▎ 摘  要

Graphene-based nanomaterials (GBNs) have many applications as biomedical materials in tissue engineering and regenerative medicine. We report on the preparation of starch-(functionalized) reduced graphene oxide nanosheets (SRGO) using soluble starch as a reducing agent in a hydrothermal method, and their in vitro interactions with human skin fibroblasts and red blood cells (RBCs). Our results indicate that soluble SRGO nanosheets were prepared using graphene oxide (GO) as a raw material. SRGO-1 and -10, which were prepared using different concentrations of soluble starch after hydrothermal treatment, were characterized by ultraviolet-visible spectroscopy and showed a peak shift at 260 nm corresponding to the deoxygenation of GO and restoration of the conjugated aromatic structure. Dynamic light scattering and zeta potential measurements were used to determine Z-average sizes and surface charges of GO and SRGOs. X-ray diffractometry, attenuated total reflectance Fourier-transform infrared spectroscopy, and Raman spectroscopy revealed the progressive elimination of labile oxygen functional groups during hydrothermal treatment and restoration of the a-conjugated network. X-ray photoelectron spectroscopy showed de-oxidation of SRGOs, which had high carbon to oxygen ratios (C/O) as compared with GO. Interactions of SRGO-1 and -10 with skin fibroblasts showed excellent biocompatibility even at a concentration of 200 mu g/ml with cell viabilities up to 88% and 90%, respectively, whereas notable cytotoxicity was observed for GO at 20 mu g/ml. Similarly, SRGO-1 and -10 did not exhibit toxicity to RBCs compared to GO. Biofilm formation and metabolic activities of biofilm by the bacterium Staphylococcus aureus were also evaluated using a crystal violet and a tetrazolium reduction assay, respectively. The described hydrothermal method used to synthesize SRGO provides a cheap, facile, and environmentally friendly means of producing water-dispersible, biocompatible and hemocompatible reduced GOs for the fabrication of novel GBNs for various biomedical applications.