• 文献标题:   Polyaniline/graphene quantum dot-modified screen-printed carbon electrode for the rapid determination of Cr(VI) using stopped-flow analysis coupled with voltammetric technique
  • 文献类型:   Article
  • 作  者:   PUNRAT E, MAKSUK C, CHUANUWATANAKUL S, WONSAWAT W, CHAILAPAKUL O
  • 作者关键词:   chromium vi, polyaniline, graphene quantum dot, stoppedflow analysi, voltammetry
  • 出版物名称:   TALANTA
  • ISSN:   0039-9140 EI 1873-3573
  • 通讯作者地址:   Chulalongkorn Univ
  • 被引频次:   30
  • DOI:   10.1016/j.talanta.2015.12.016
  • 出版年:   2016

▎ 摘  要

Polyaniline/graphene quantum dots (PANI/GQDs) were used to modify a screen-printed carbon electrode (SPCE) in a flow-based system. A method for rapidly determining the Cr(VI) concentrations by using stopped-flow analysis has been developed using an Auto-Pret system coupled with linear-sweep voltammetry using the PANI/GQD-modified SPCE. The GQDs, synthesized in a botton-up manner from citric acid, were mixed with aniline monomer in an optimized ratio. The mixture was injected into an electrochemical flow cell in which electro-polymerization of the aniline monomer occurred. Under conditions optimized for determining Cr(VI), wide linearity was obtained in the range of 0.1-10 mg L-1, with a detection limit of 0.097 mg L-1. For a sample volume of 0.5 mL, the modified SPCE can be used continuously with a sample-throughput of more than 90 samples per hour. In addition, this proposed method was successfully applied to mineral water samples with acceptable accuracy, and the quantitative agreement was accomplished in deteriorated Cr-plating solutions with a standard traditional method for Cr(VI) detection. (C) 2015 Elsevier B.V. All rights reserved.