• 文献标题:   A nanocomposite prepared from magnetite nanoparticles, polyaniline and carboxy-modified graphene oxide for non-enzymatic sensing of glucose
  • 文献类型:   Article
  • 作  者:   BATOOL R, AKHTAR MA, HAYAT A, HAN DX, NIU L, AHMAD MA, NAWAZ MH
  • 作者关键词:   screen printed carbon electrode, functionalized graphene oxide, iron oxide, polyaniline, electrochemical sensor, glucose detection, serum sample, enzyme free glucose sensor, metal oxide decorated graphene
  • 出版物名称:   MICROCHIMICA ACTA
  • ISSN:   0026-3672 EI 1436-5073
  • 通讯作者地址:   COMBATS Univ Islamabad
  • 被引频次:   13
  • DOI:   10.1007/s00604-019-3364-2
  • 出版年:   2019

▎ 摘  要

The authors report on the synthesis of carboxy functionalized graphene oxide (fGO) decorated with magnetite (Fe3O4) nanoparticles. The resulting nanomaterial was used to prepare a composite with polyaniline (PANI) which was characterized by UV-vis, Fourier transform-infrared and Raman spectroscopies. Its surface morphologies were characterized by atomic force and scanning electron microscopies. A screen-printed carbon electrode was then modified with the nanocomposite to obtain an enzyme-free glucose sensor. The large surface of fGO and Fe3O4 along with the enhanced charge transfer capability of PANI warrant a pronounced electrochemical response (typically measured at 0.18V versus Ag/AgCl) which is suppressed in the presence of glucose. This reduction of current by glucose was used to design a sensitive method for quantification of glucose. The response of the modified SPCE is linear in the 0.05M - 5mM glucose concentration range, and the lower detection limit is 0.01M.