• 文献标题:   Co3O4-CuNi/reduced graphene composite for non-enzymatic detection of ascorbic acid
  • 文献类型:   Article
  • 作  者:   DU JW, TAO YY, ZHANG J, XIONG ZC, XIE AJ, LUO SP, LI XZ, YAO C
  • 作者关键词:   co3o4cuni, rgo, graphene, ascorbic acid, nonenzymatic sensor
  • 出版物名称:   MATERIALS TECHNOLOGY
  • ISSN:   1066-7857 EI 1753-5557
  • 通讯作者地址:   Changzhou Univ
  • 被引频次:   2
  • DOI:   10.1080/10667857.2019.1612551 EA MAY 2019
  • 出版年:   2019

▎ 摘  要

A novel Co3O4-CuNi/graphene (Co3O4-CuNi/RGO) composite was developed by two-step hydrothermal method and used as non-enzymatic electrochemical sensor for ascorbic acid (AA) detection. A series of electrochemical detections declared that Co3O4-CuNi/RGO-modified glassy carbon electrode (GCE) has good electrocatalytic activity against AA oxidation, and the optimised sensor has low detection limit (0.34 mu M), excellent stability, repeatability and selectivity. In the concentration range of 10-100 mu M, the response current of the as-fabricated Co3O4-CuNi/RGO AA sensor is proportional to the AA concentration, and the linear equation can be denoted as I-pa(mA) = 1.006 + 0.378C (mu M), the correlation coefficient R-2 = 0.9917. Moreover, as compared to other reported electrodes, Co3O4-CuNi/RGO-modified GCE exhibited a comparable detection limit and provided a simple, easy, low-cost, and non-enzymatic method for AA detection. This highly sensitive Co3O4-CuNi/RGO can be further expanded to detect AA in vitamin C tablets, orange, vitamin water and other real samples.