• 文献标题:   A colloidal suspension of nanostructured poly(N-butyl benzimidazole)-graphene sheets with high oxidase yield for analytical glucose and choline detections
  • 文献类型:   Article
  • 作  者:   CHEN HC, TSAI RY, CHEN YH, LEE RS, HUA MY
  • 作者关键词:   poly nbutyl benzimidazole, graphene sheet, hydrogen peroxide, glucose, choline, electrostatic attraction
  • 出版物名称:   ANALYTICA CHIMICA ACTA
  • ISSN:   0003-2670
  • 通讯作者地址:   Chang Gung Univ
  • 被引频次:   15
  • DOI:   10.1016/j.aca.2013.07.006
  • 出版年:   2013

▎ 摘  要

A colloidal suspension of nanostructured poly(N-butyl benzimidazole)-graphene sheets (PBBIns-Gs) was used to modify a gold electrode to form a three-dimensional PBBIns-Gs/Au electrode that was sensitive to hydrogen peroxide (H2O2) in the presence of acetic acid (AcOH). The positively charged nanostructured poly(N-butyl benzimidazole) (PBBIns) separated the graphene sheets (Gs) and kept them suspended in an aqueous solution. Additionally, graphene sheets (Gs) formed "diaphragms" that intercalated Gs, which separated PBBIns to prevent tight packing and enhanced the surface area. The PBBIns-Gs/Au electrode exhibited superior sensitivity toward H2O2 relative to the PBBIns-modified Au (PBBIns/Au) electrode. Furthermore, a high yield of glucose oxidase (GOD) on the PBBIns-Gs of 52.3 mg GOD per 1 mg PBBIns-Gs was obtained from the electrostatic attraction between the positively charged PBBIns-Gs and negatively charged GOD. The non-destructive immobilization of GOD on the surface of the PBBIns-Gs (GOD-PBBIns-Gs) retained 91.5% and 39.2% of bioactivity, respectively, relative to free GOD for the colloidal suspension of the GOD-PBBIns-Gs and its modified Au (GOD-PBBIns-Gs/Au) electrode. Based on advantages including a negative working potential, high sensitivity toward H2O2, and non-destructive immobilization, the proposed glucose biosensor based on an GOD-PBBIns-Gs/Au electrode exhibited a fast response time (5.6 s), broad detection range (10 mu M to 10 mM), high sensitivity (143.5 mu A mM(-1) cm(-2)) and selectivity, and excellent stability. Finally, a choline biosensor was developed by dipping a PBBIns-Gs/Au electrode into a choline oxidase (ChOx) solution for enzyme loading. The choline biosensor had a linear range of 0.1 mu M to 0.83 mM, sensitivity of 494.9 mu A mM(-1) cm(-2), and detection limit of 0.02 mu M. The results of glucose and choline measurement indicate that the PBBIns-Gs/Au electrode provides a useful platform for the development of oxidase-based biosensors. (c) 2013 Elsevier B.V. All rights reserved.