▎ 摘 要
Here, a highly sensitive and selective copper ion (Cu2+) fluorescence sensor is reported. The Hematoporphyrin functionalized Graphene Oxide (HP-GO) fluorescence sensor were synthesized via esterification reaction between Graphene Oxide and Hematoporphyrin (HP). The HP-GO sensor was fully characterized by Fourier Transform Infrared Spectroscopy (FTIR), X-ray diffraction (XRD), Scanning Electrom Microscopy (SEM), UV-Vis spectroscopy, Transmission Electron Microscopy (TEM), Fluor meter spectroscopy, X-Ray photoelectron spectroscopy(XPS), and Raman spectroscopy measurements. The HP GO sensor advertised two linear regions over the range of 0-1.18 x 10(3) nM and 3.93 x 10(3) to 47.27 nM of copper (II) with detection limit of 54 nM in the aqueous solution. The selectivity of HP-GO for Cu2+ is much higher than that of other metal ions due to the presence of aza macrocyclic ring on the surface of HP-GO which has a high binding affinity with Cu2+. Additionally, the HP-GO shows wide pH viable range (pH 6-10). The effect of other metal ions on the fluorescence intensity of the HP-GO was also studied and other metal ions show a low interference response in the detection of Cu2+. HP-GO sensor manifests advantages of high reproducibility (The quenched fluorescence of HP/GO-Cu can be recovered by EDTA), attractive long term fluorescence stability (>21 days) in water, also remarkable selectivity regarding number of metal ions (Na+, K+, Ca2+, Fe3+, Fe2+, Al3+, Pb2+, Mn2+, Mg2+, Co2+, Ni2+, Cr6+, Cd2+, Hg2+, and Zn2+), low toxicity and can detect Cu2+ in real water samples which acquire well for its promising in environmental applications. (c) 2020 Elsevier B.V. All rights reserved.