▎ 摘 要
In this work, The hybrid hydroxyapatite (HaP), chitosan (CH) and graphene nanosheets (GNS) mixtures were applied by electrospinning on the surface of GNS and Si3N4 (SN) binary powder reinforced hybrid titanium (Ti) metal composites surface to improve composite biosurface functionallity. The surfaces of coated materials were characterized and antibacterial tests were carried on for their suitability in the industry by performing artificial body fluid tests. The hybrid nano fiber coatings formed a homogeneous structure on the composite. According to bioactivity tests and microstructure analysis, it was seen that HaP, which has the best results in the change of pH (pH= 11.80) values. The lowest mass change (0.0005 g) was observed on the 10th day of pure titanium. The highest mass change (0.0210 g) was obtained as on the HaP coated hybrid titanium composite. According to the antibacterial test result the hybrid nanofiber containing silver (Ag+) doped HaP on Ti composites showed the best antibacterial property aganist the E.coli. The fabricated electrospin coated hybrid composites can be a potantial candidate for dental, orthopedic implant applications and tissue engineering.