• 文献标题:   Development of porous polymer pressure sensors incorporating graphene platelets
  • 文献类型:   Article
  • 作  者:   GONCALVES V, BRANDAO L, MENDES A
  • 作者关键词:   polymermatrix composites pmcs, foam, smart material, graphene platelet
  • 出版物名称:   POLYMER TESTING
  • ISSN:   0142-9418 EI 1873-2348
  • 通讯作者地址:   Univ Porto
  • 被引频次:   11
  • DOI:   10.1016/j.polymertesting.2014.05.010
  • 出版年:   2014

▎ 摘  要

Electrically conductive polymer composites (ECPCs) based on porous polymeric matrices of PEBA 4033 incorporating different types of graphene platelets were prepared and tested. PEBA 4033 polymer was mixed with different graphene platelets: grade H5, grade MX and grade C-750. Porous morphology was obtained for the ECPCs prepared with graphene platelets grade MX and H5, while for the grade C-750 only a dense ECPCs was obtained. The porous ECPC loaded with 15 vol.% of graphene M5 exhibited a linear piezoresistive response oin a log-log plot. Some limitations were detected for this ECPC, namely hysteresis and drift due to the poor mechanical properties. The porous ECPC loaded with 15 vol.% M5 was further crosslinked, which improved its mechanical properties but the piezoresistive effect became negligible. The incorporation of carbon black in this ECPC formulation was shown to be much more efficient than crosslinking to improve mechanical properties, but the piezoresistive response became poor. (C) 2014 Elsevier Ltd. All rights reserved.