• 文献标题:   Highly selective amperometric nitrite sensor based on chemically reduced graphene oxide modified electrode
  • 文献类型:   Article
  • 作  者:   MANI V, PERIASAMY AP, CHEN SM
  • 作者关键词:   chemically reduced graphene oxide, nitrite, amperometry, electrocatalysi
  • 出版物名称:   ELECTROCHEMISTRY COMMUNICATIONS
  • ISSN:   1388-2481 EI 1873-1902
  • 通讯作者地址:   Natl Taipei Univ Technol
  • 被引频次:   218
  • DOI:   10.1016/j.elecom.2012.02.009
  • 出版年:   2012

▎ 摘  要

Herein, we report a highly selective amperometric nitrite sensor using a chemically reduced graphene oxide (CR-GO) modified glassy carbon electrode (GCE). The nitrite oxidation peak current (I-P) at CR-GO/GCE was 1.3 and 2.2 fold higher than that of electrochemically reduced graphene oxide (ER-GO) and unmodified GCEs respectively. Moreover, nitrite oxidation at CR-GO/GCE occurred at + 0.8 V, roughly 80 and 130 mV lower potential than ER-GO and unmodified GCEs respectively. CR-GO/GCE detects nitrite in the linear range of 8.9-167 mu M, with a sensitivity of 0.0267 A M-1. The limit of detection (LOD) was 1 mu M. This sensor selectively detects nitrite even in the presence of 1000/250 fold of common ions and biological interferrants. CR-GO/GCE also demonstrates an excellent operational stability and good antifouling properties. The excellent recovery (similar to 99%) achieved for nitrite determination in various water samples reveal its promising practicality. (C) 2012 Elsevier B.V. All rights reserved.