▎ 摘 要
The modified electrode of polyaniline/graphene (PANI/Gr) composites was prepared by in situ electrochemical synthesis of aniline monomer and graphene oxide in hydrochloric acid. The PANI/Gr composites modified electrodes were utilized for fabricating the highly sensitive, reliable and reproducible hydrazine chemical sensor. The PANI/Gr composites modified electrodes were extensively characterized by morphological, structural and the optical properties. The Raman studies revealed that PANI/Gr composite modified electrode possessed both Gr and PANI Raman bands, suggested the pi-pi* electron interaction between C-N+center dot of PANI and carboxylate group of Gr. The sensing performance of the fabricated chemical sensor toward the detection of hydrazine was measured by a two electrode current-voltage (I-V) technique. A very high sensitivity of similar to 32.54 x 10(-5) A cm(-2) mM(-1) and reasonable detection limit of similar to 15.38 mM with correlation coefficient (R) of 0.78578 and short response time (10 s) were observed by PANI/Gr composites modified thin film electrode. (C) 2012 Elsevier B.V. All rights reserved.