• 文献标题:   Electrooxidation Behavior and Amperometric Determination of Sotalol on a Graphene Oxide Nanosheets-modified Glassy Carbon Electrode
  • 文献类型:   Article
  • 作  者:   HELI H, ZARE SN, SATTARAHMADY N, KARIMIAN K
  • 作者关键词:   graphene, sotalol, modified electrode, electrocatalysi, nanosensor
  • 出版物名称:   CURRENT PHARMACEUTICAL ANALYSIS
  • ISSN:   1573-4129 EI 1875-676X
  • 通讯作者地址:   Iranian Space Res Ctr
  • 被引频次:   9
  • DOI:   10.2174/1573412911309030007
  • 出版年:   2013

▎ 摘  要

The electrochemical behavior of sotalol was investigated on a graphene oxide nanosheets-modified glassy carbon electrode in a phosphate buffer solution, pH 7.4. Cyclic voltammetry and chronoamperometry were employed to obtain information about the electrooxidation process. During the electrooxidation of sotalol, one irreversible anodic peak appeared in the voltammograms. Some kinetic parameters, such as the diffusion and charge transfer coefficients were obtained. An amperometric procedure was developed for the determination of sotalol, a detection limit of 7.57 mu M, a linear dynamic range of 0.1 to 2.24 mM, and a calibration sensitivity of 0.945 mA M-1 were obtained. The method was applied to the analysis of sotalol tablets, and applicability of the method to direct assays of spiked human serum and urine fluids was investigated.